Raised floor
Raised server room floors are the hallmark of the high-availability enterprise data center,
and with good reason. For many companies, the presentation of their data center is an important part of facility tours for key customers. Data centers and server rooms without raised floors are perceived as being incomplete or less than state of the art.
The raised flooring within server rooms was developed to provide the following:

  • A distribution system for conditioned cold air
  • Tracks, conduits, and/or supports for data cabling
  • Conduits for power cabling
  • A copper ground grid for grounding of equipment
  • A location to run chilled water and/or other CRAC piping

Needs for conditioned cold air and power distribution contribute to the popularity of raised floors. Both operations people and server room design firms value the flexibility that is provided by raised floor systems. Regarding power requirements, the number of branch circuits per square foot in today's data center is much greater than in the past. In most cases, it is easier to install and maintain under-floor branch circuits than ceiling-mounted branch circuits. Although, a recent trend is to utilize a power and data cable pathway as part of the cabinet system. This effectively reduces the cable quantities under the raised floor, thereby allowing for greater open space dedicated to air distribution. In general, raised server room floors are a predictable and practical design option for most facilities.
From installing raised server room floors to monitoring increasing power requirements, PTS Data Center Solutions is the ideal provider for planning and designing server rooms and helping to maintain and monitor them once installation in complete. For results you can count on, let PTS continue to serve you throughout the implementation and maintenance process.

Soluflex serviced floor system
 is a new concept. It allows one person to install approximately 100 Sq metres in one day, in a clear area.  Services can then be easily installed under the floor. More importantly the access to these services is easily reachable from any position on the floor, by simply lifting a tile. 30% of new workstations change position in their first year of life, so the flexibility of change of the Soluflex system is a key benefit to the final user.

Residential Door entry system, with flush-mounting flat screen video internal handset. Different surround plates can be clipped on to suit any decor. Standard video and audio handsets can be installed in addition to the top-of-the-line flush unit, and work together.

Synergy switches & sockets incorporating multi-room audio and lighting scenario control Soluflex Commercial Serviced Floor offer. Any electrical function that is needed for a house or hotel can be easily achieved in one of 10 different finishes. Total safety is assured for children with the 3-point safety shutters on power sockets.